This Floor standing Fast DC charger is designed for Commercial use, With 50KW and up to 112A current, DC charging will emerge in more and more locations. Using self-developed 50KW power module, the charger design is highly integrated and compact, with protection grade up to IP54, which is suitable for both indoor and outdoor applications. Equipped with a CCS2 charging gun,its easy operation as plug-and-play makes it an ideal solution for the fleet or parking facilities.

Please contact us to obtain price offer
0
Enter your email
Delivery within on request
Shipping price The Lack Of
The Availability Of Out of the stock
The Weight Of The 225 kg
Leave your phone
Key Features & Benefits
  • Delicate appearance, simple operation, convenient installation;
  • High efficiency, reliable and stable performance;
  • Friendly interaction interface, 7inch touch screen;
  • Support multiple modes of charging, operation management and payment;
  • Support RS232/435/CAN, Ethernet or wireless;
  • Support RFID Card/OCPP1.6;
  • Support IEC62196-2 Type-2 / CCS2 / CHAdeMO;
  • Overload integrated Protection;
  • Support online data upgrade.
Technical Parameter
  • EV charger Type: DC and AC
  •  Charger Capacity: 142KW (60KW CCS2 + 60KW CHAdeMO + 22KW Type2)
  • Mounting: Floor standing
    Input Requirements
  • AC Supply System: Three-Phase, 5 Wire AC system
  • Nominal Input voltage: 260V t0 530V (+20% and -20%)
  • Input frequency: 50Hz, ±1.5Hz / 60Hz, ±1.5Hz
             Mechanical Requirements
  • IP Ratings: IP 54
  • Cooling: Forced air cooled
    Output Requirements
  • Number of outputs:3
  • Type of each output: 250-750VDC (+20% and -20%)
  • Output Current: Max. 112Amp
  • Power Factor: ≥0.99(50% load above)
  • User Interface & Display Requirements
  • Display & touch-screen size: 7 inches
  • User Authentication: Mobile application or User interface / QR Code/RFID Card/Password Login
  • Metering Information: Consumption Units
Communication Requirements
  • Communication: OCPP 1.6 protocol
  • Charger and CMS: Ethernet / WIFI and GPRS Modem
Protection & Safety Requirements
  • Safety Parameters: Over current, under voltage, Residual current, Surge protection, leakage protection, Short circuit, Over temperature, etc.
  • Power failure: If there is a power failure, user is indicated about this.
There is currently no comments or ratings for this product.